Main parameter and technical performance
Dissipated power (during the impulse) |
19 VA |
Illuminated PB control |
Max. current 3 mA (if > use an ATLz) |
Operating threshold |
Min. 85 % of Un |
Duration of the control order |
50 ms to 1 s (200 ms recommended) |
Response time |
50ms |
Power circuit |
Voltage rating |
|
250V AC |
Frequenc |
50/60Hz |
Maximum number of operations per minute |
5 |
Maximum number of switching operation
a day |
100 |
Endurance |
200,000 cycles(AC21) |
100,000 cycles(AC22) |
Overvoltage category |
IV |
Insulation voltage |
440 V AC |
Pollution degree |
3 |
Rated impulse withstand voltage |
6kV |
Degree of protection |
Device only |
IP20 |
Device in modular |
Ip40(Insulation class II) |
Operating temperature |
-5ºC~+60ºC |
Storage temperature |
-40ºC~+70ºC |
Tropicalization |
Treatment 2
(relative humidity 95 % at 55ºC |
|
|
Features
Reliable Quality
Continue operation 10000 times action reliable and accurately respond to commands
Hum Free
Reduce the Pull-in noise
Hide the clamp holder
The concealed lamp had patented make an auxiliary that is more flexible and easy to mounting,
which not only improves the aesthetics of the product,but also increases the strength of the device
Class H high temperature resistant enameled wire
Automatic winding process to ensure reliable opening and closing of the coil
Easy Operation
Through O-I shift to priority manual control directly. The handle position as mechanical indicator
Detailed Photos
The table below shows the maximum number of light fittings for each relay, according to the type, power and configuration of a given lamp. As an indication, the total acceptable power is also mentioned. These values are given for a 230 V circuit with 2 active conductors (single-phase phase/neutral or two-phase phase/phase). For 110 V circuits, divide the values in the table by 2.To obtain the equivalent values for the entire 230 V three-phase circuit, multiply the number of lams and the maximum power output: by (1.73) for circuits with 230 V between phases without neutral; by for circuits with 230 V between phase and neutral or 400 V between phases.
Note: The power ratings of the lamps most commonly used are shown in bold. For powers not mentioned, use a proportional rule with the nearest values.
Company Profile
FAQ
Q: Are you trading company or manufacturer ?
A: We are manufacturer. We have 30,000 square meters of self-owned plant.
Q: Do you have any certificates?
A: Yes,we have UL, TUV, CB, SAA, CCC, CE and other certifications.
Q: How do we make a quick response to customer , 5 inquiry ?
A: Our professional team will reply you online or by email,Skype, whatsApp and so on.
Q: Do you have any exporting experience?Which countries did you export to before?
A: We have lots of exporting experience and customers in many countries,such as America, Japan,Australia,UAE,Canada,Vietnam,Turkey,Thailand,Russia,UK,etc.
Q:Can you supply samples for checking ?
A: Yes, we can supply samples, pls contact for detailed required.
Q:How long is your delivery time?
A: Generally it is within 3days for small qty. Or it is around 15-20 days to a general order.
Q: What is the standard of package of your goods?
A: Export standard package or special package according to customer requirement.
Q:How about inspection?
A: We have the whole inspection system from raw material to end products include transient test, delay test,mechanical life test and so on.Q:What is the service offered by company?
A: We have the professional engineer team which can design and develop the mould to arrive different customer requirements. We also have the professional sales team to offer good service from pre-sale to after-sale