Customization: | Available |
---|---|
Type: | Signal Type Arrester |
Structure: | Protective Gap |
Still deciding? Get samples of US$ 18.6/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
EAP Series Surge Protection Device was designed and manufactured, complying standard GB/T18802.1 /EN 61643-11 , Rated voltage 275V~,320V~,385V~, Maximum discharge current 40kA,High Energy Varistor, high effective for lightning protection.
Product Benefits
Technical Data
IEC Electrical | |||||||
Nominal AC Voltage (50/60Hz) | Uo /Un | 60V | 120V | 230V | 230V | 230V | 230V |
Maximum Continuous Operating Voltage (AC) | Uc | 75V | 150V | 275V | 320V | 385V | 420V |
Nominal Discharge Current (8/20 μs) | In | 20kA | 20kA | 20kA | 20kA | 20kA | 20kA |
Maximum Discharge Current (8/20 μs) | Imax | 40kA | 40kA | 40kA | 40kA | 40kA | 40kA |
Voltage Protection Level | Up | 400V | 1000V | 1400V | 1400V | 1800V | 2000V |
Response Time | tA | <25ns | |||||
Back-Up Fuse (max) | 125A gL / gG | ||||||
Short-Circuit Current Rating (AC) | I SCCR | 25kA / 50kA | |||||
TOV Withstand 5s | UT | 335V | |||||
UT | 440V | ||||||
TOV 120min | Mode | Safe Fail | |||||
Number of Ports | 1 | ||||||
UL Electrical | |||||||
Maximum Continuous Operating Voltage (AC) | MCOV | 75V | 150V | 275V | 320V | 385V | 420V |
Voltage Protection Rating | VPR | 330V | 600V | 900V | 1000V | 1200V | 1400V |
Nominal Discharge Current (8/20 μs) | In | 20kA | 20kA | 20kA | 20kA | 20kA | 20kA |
Short-Circuit Current Rating (AC) | I SCCR | 150kA | 150kA | 150kA | 150kA | 150kA | 150kA |
Mechanical & Environmental | |||||||
Operating Temperature Range | Ta | -40oF to +158oF [-40oC to +70oC] | |||||
Permissible Operating Humidity | RH | 5%…95% | |||||
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500m … 2000m | ||||||
Terminal Screw Torque | Mmax | 39.9 Ibf·in [2.0~2.5 N.m] | |||||
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) | ||||||
35mm2 (Solid, Stranded) / 25mm2 (Flexible) | |||||||
Mounting | 35mm DIN Rail, EN 60715 | ||||||
Degree of Protection | IP20(built-in) | ||||||
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 | ||||||
Thermal Protection | Yes | ||||||
Operating State / Fault Indication | Green: ok / Red: failure | ||||||
Remote Contacts (RC) | Optional | ||||||
RC Switching Capacity | AC:250V / 0.5A; DC:250V / 0.1A; 125V / 0.2A; 75V / 0.5A | ||||||
RC Conductor Cross Section (max) | 16AWG (Solid) / 1.5mm2 (Solid) |