Customization: | Available |
---|---|
Type: | Low-voltage |
Structure: | Single-column Disconnector |
Still deciding? Get samples of US$ 19/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC Isolator switches are devices or systems that isolate a particular circuit for maintenance and prevent currents from passing through. The main isolator switch, also known as an isolator, typically consists of two sets (or one set) of electrical contacts mounted in series. The line side is connected to a power supply outside the building.
Product Benefits
Technical Data
No | Description | Code |
1 | Type of Switch disconnectors | EAS80- |
2 | Installation Form | DB:Rail mounting DC:Door interlocked ELA:Aluminum enclosure box
PM:Panel mounting EL:Plastic enclosure box |
3 | Rated current(A) | 16:16A 20:20A 25:25A 32:32A 40:40A 63:63A
80:80A 80H:100A 100:100A 125:125A |
4 | Knob Lock | Nil:Without lock R:With lock |
5 | Poles | 2P 3P 4P 6P 8P |
6 | Knob color | Nil:Blue knob BW:Black/white rotating handle G:Gray knob Optional with lock RY:Rotating red/yellow handle BB:Rotating black/black handle
With lock without lock |
7 | Inter lock mechanism | IM2:sync IM31:normal close IM32:normal open |
Short circuit withstand current of fuse protection (kA rms expected value)
Fuse class | 415V | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 125A | |
Rated conditional short-circuit current |
415V |
10kA |
15kA |
20kA |
|||||||
Short circuit withstand current of circuit breaker for protection, any circuit breaker that can trip within 0.3s
Rated short-time withstand current |
0.3S |
2.5kA |
3kA |
5kA |
Short circuit performance (unprotected)
Rated short-time withstand current |
1S |
1.0kA |
1.5kA |
2.5kA |
Rated short circuit making capacity |
0.8kA |
1.4kA |
2.1kA |
|
Cable cross section | 1.5~10mm² | 2.5~35mm² | 10~70mm² | |
Rated insulation voltage Ui | 800V | |||
Rated impulse withstand voltage Uimp |
8kV |
|||
Mechanical Endurance | 100000 | |||
Ambient Temperature | Operating -25~+55°C Storage -40~+70°C |
Short circuit withstand current of fuse protection (kA rms expected value)
Fuse class | 415V | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 125A | |
Rated conditional short-circuit current |
415V |
10kA |
15kA |
20kA |
|||||||
Short circuit withstand current of circuit breaker for protection, any circuit breaker that can trip within 0.3s
Rated short-time withstand current |
0.3S |
2.5kA |
3kA |
5kA |
Short circuit performance (unprotected)
Rated short-time withstand current |
1S |
1.0kA |
1.5kA |
2.5kA |
Rated short circuit making capacity |
0.8kA |
1.4kA |
2.1kA |
|
Cable cross section | 1.5~10mm² | 2.5~35mm² | 10~70mm² | |
Rated insulation voltage Ui | 800V | |||
Rated impulse withstand voltage Uimp |
8kV |
|||
Mechanical Endurance | 100000 | |||
Ambient Temperature | Operating -25~+55°C Storage -40~+70°C |