EAP Series Surge Protection Device was designed and manufactured, complying standard GB/T18802.1 IEC/EN 61643-11 , Rated voltage 275V~,320V~,385V~,440V~,Maximum discharge current 50kA,High Energy Varistor, high effective for lightning protection.
AC Surge Protection Device SPD Type 1 2, T1 T1, B C, I II, Iimp 10kA,lmax 100kA is designed to be the best possible solution for protecting service entrances at industrial sites, particularly those with existing lightning protection systems or mesh cage applications. This sort of surge protection can protect all electrical installations from lightning strikes by discharging the current generated by a lightning surge and preventing its spread to the equipment. The current waveform of the Type 1 2/Class B C, I II SPD is 10/350 μs.
Product Benefits
Technical Data
IEC Electrical | ||
Nominal AC Voltage (50/60Hz) | Uo /Un | 230V 230V 230V 400V |
Maximum Continuous Operating Voltage (AC) | Uc | 275V 320V 385V 440V |
Nominal Discharge Current (8/20 μs) | In | 20kA 20kA 20kA 20kA |
Maximum Discharge Current (8/20 μs) | Imax | 50kA 50kA 50kA 50kA |
Impulse Discharge Current (10/350 μs) | I Imp | 12.5kA 12.5kA 10kA 10kA |
Specific Energy | W/R | 39kJ/Ω 39kJ/Ω 25kJ/Ω 25kJ/Ω |
Charge | Q | 6.25As 6.25As 5As 5As |
Voltage Protection Level | Up | 1500V 1500V 1800V 2000V |
Response Time | tA | <25ns |
Back-Up Fuse (max) | 160A gL | |
Short-Circuit Current Rating (AC) | I SCCR | 25kA / 50kA |
TOV Withstand 5s | UT | 335V 335V 335V 580V |
UT | 440V 440V 440V 765V | |
TOV 120min | Mode | Safe Fail Safe Fail Safe Fail Safe Fail |
Number of Ports | 1 | |
UL Electrical | ||
Maximum Continuous Operating Voltage (AC) | MCOV | 275V 320V 385V 440V |
Voltage Protection Rating | VPR | 900V 1200V 1350V 1500V |
Nominal Discharge Current (8/20 μs) | In | 20kA 20kA 20kA 20kA |
Short-Circuit Current Rating (AC) | SCCR | 150kA 150kA 150kA 200kA |
Mechanical & Environmental | ||
Operating Temperature Range | Ta | -40oF to +158oF [-40oC to +70oC] |
Permissible Operating Humidity | RH | 5%…95% |
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500m … 2000m | |
Terminal Screw Torque | Mmax | 39.9 Ibf·in [2.0~2.5 N.m] |
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) | |
35mm2 (Solid, Stranded) / 25mm2 (Flexible) | ||
Mounting | 35mm DIN Rail, EN 60715 | |
Degree of Protection | IP20(built-in) | |
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 | |
Thermal Protection | Yes | |
Operating State / Fault Indication | Green: ok / Red: defect | |
Remote Contacts (RC) | Optional | |
RC Switching Capacity | AC:250V / 0.5A; DC:250V / 0.1A; 125V / 0.2A; 75V / 0.5A | |
RC Conductor Cross Section (max) | 16AWG (Solid) / 1.5mm2 (Solid) |
Product model | |||||
IEC Electrical | |||||
Nominal AC Voltage (50/60Hz) | Uo /Un | 230V | |||
Maximum Continuous Operating Voltage (AC) (L-N) / (N-PE) | Uc | 275V/255V | 320V/255V | 385V/255V | 440V/440V |
Nominal Discharge Current (8/20 μs) (L-N) / (N-PE) | In | 20kA/20kA | 20kA/20kA | 20kA/20kA | 20kA/20kA |
Maximum Discharge Current (8/20 μs) (L-N) / (N-PE) | Imax | 50kA/50kA | 50kA/50kA | 50kA/50kA | 50kA/50kA |
(L-N) / (N-PE) | I Imp | 12.5kA / 25kA / 50kA | |||
Voltage Protection Level (L-N) / (N-PE) | Up | <1500V / 1500V | <1500V / 1500V | <1800V / 1500V | <2000V / 1500V |
Response Time (L-N) / (N-PE) | tA | <25ns / 100ns | |||
Back-Up Fuse (max) | 160A gL | ||||
Short-Circuit Current Rating (AC) (L-N) | I SCCR | 25kA / 50kA | |||
TOV Withstand 5s (L-N) | UT | 335V | |||
(L-N) | UT | 440V | |||
TOV 120min (L-N) | Mode | Safe Fail | |||
Number of Ports | 1 | ||||
UL Electrical | |||||
Maximum Continuous Operating Voltage (AC) | MCOV | 275V | 320V | 385V | 440V |
Voltage Protection Rating | VPR | 900V | 1000V | 1200V | 1200V |
Nominal Discharge Current (8/20 μs) | In | 20kA | 20kA | 20kA | 20kA |
Short-Circuit Current Rating (AC) | I SCCR | 150kA | 150kA | 150kA | 200kA |
Mechanical & Environmental | |||||
Operating Temperature Range | Ta | -40oF to +158oF [-40oC to +70oC] | |||
Permissible Operating Humidity | RH | 5%…95% | |||
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500m … 2000m | ||||
Terminal Screw Torque | Mmax | 39.9 Ibf·in [2.0~2.5 N.m] | |||
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) | ||||
35mm2 (Solid, Stranded) / 25mm2 (Flexible) | |||||
Mounting | 35mm DIN Rail, EN 60715 | ||||
Degree of Protection | IP20(built-in) | ||||
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 | ||||
Thermal Protection | Yes | ||||
Operating State / Fault Indication | Green: ok / Red: failure | ||||
Remote Contacts (RC) | Optional | ||||
RC Switching Capacity | AC:250V / 0.5A; DC:250V / 0.1A; 125V / 0.2A; 75V / 0.5A | ||||
RC Conductor Cross Section (max) | 16AWG (Solid) / 1.5mm2 (Solid) |
Product model | |||||
IEC Electrical | |||||
Nominal AC Voltage (50/60Hz) | Uo /Un | 230V | |||
Maximum Continuous Operating Voltage (AC) (L-N) / (N-PE) | Uc | 275V/255V | 320V/255V | 385V/255V | 440V/440V |
Nominal Discharge Current (8/20 μs) (L-N) / (N-PE) | In | 20kA/20kA | 20kA/20kA | 20kA/20kA | 20kA/20kA |
Maximum Discharge Current (8/20 μs) (L-N) / (N-PE) | Imax | 50kA/50kA | 50kA/50kA | 50kA/50kA | 50kA/50kA |
(L-N) / (N-PE) | I Imp | 12.5kA / 25kA / 50kA | |||
Voltage Protection Level (L-N) / (N-PE) | Up | <1500V / 1500V | <1500V / 1500V | <1800V / 1500V | <2000V / 1500V |
Response Time (L-N) / (N-PE) | tA | <25ns / 100ns | |||
Back-Up Fuse (max) | 160A gL | ||||
Short-Circuit Current Rating (AC) (L-N) | I SCCR | 25kA / 50kA | |||
TOV Withstand 5s (L-N) | UT | 335V | |||
(L-N) | UT | 440V | |||
TOV 120min (L-N) | Mode | Safe Fail | |||
Number of Ports | 1 | ||||
UL Electrical | |||||
Maximum Continuous Operating Voltage (AC) | MCOV | 275V | 320V | 385V | 440V |
Voltage Protection Rating | VPR | 900V | 1000V | 1200V | 1200V |
Nominal Discharge Current (8/20 μs) | In | 20kA | 20kA | 20kA | 20kA |
Short-Circuit Current Rating (AC) | I SCCR | 150kA | 150kA | 150kA | 200kA |
Mechanical & Environmental | |||||
Operating Temperature Range | Ta | -40oF to +158oF [-40oC to +70oC] | |||
Permissible Operating Humidity | RH | 5%…95% | |||
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500m … 2000m | ||||
Terminal Screw Torque | Mmax | 39.9 Ibf·in [2.0~2.5 N.m] | |||
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) | ||||
35mm2 (Solid, Stranded) / 25mm2 (Flexible) | |||||
Mounting | 35mm DIN Rail, EN 60715 | ||||
Degree of Protection | IP20(built-in) | ||||
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 | ||||
Thermal Protection | Yes | ||||
Operating State / Fault Indication | Green: ok / Red: failure | ||||
Remote Contacts (RC) | Optional | ||||
RC Switching Capacity | AC:250V / 0.5A; DC:250V / 0.1A; 125V / 0.2A; 75V / 0.5A | ||||
RC Conductor Cross Section (max) | 16AWG (Solid) / 1.5mm2 (Solid) |