Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 9.9/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
17000000 RMB
Plant Area
101~500 square meters
  • Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
  • Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
  • Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
  • Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
  • Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
  • Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
ESRO
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
RCBO
Poles Number
2p, 4p
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO
Certification
CE, SAA
Rated Voltage
230/400V AC
Application
Solar PV System/EV Charger System
Inc
6/10ka
Electrical and Mechanical Life
20000
Energy Limiting
Class 3
Rated Conditional Short-Circuit Current(
6000A / 10000A
Rated Current
6-63A
Transport Package
by Sea/Air
Specification
box
Trademark
Onccy
Origin
China
HS Code
8536490090
Production Capacity
1000000PC/Year

Packaging & Delivery

Package Size
50.00cm * 50.00cm * 50.00cm
Package Gross Weight
1.000kg

Product Description

Product Description

The AC Residual Current Circuit breaker is a safety appliance that protects personal safety and prevents electrical fires, can prevent electrical equipment from being damaged. It can be widely used in power distribution systems.

 

Product Benefits :

  • Air circulation
    When two poles are placed adjacent to each other, these channels form a tunnel resulting in effective air circulation around individual poles
  • Bi-connect Termination Possible
    Choice to use Busbar and/or cable in the same terminal,provides reliable termination
  • Din Rail Mounting
    Two step snapping mechanism for easy & efficient mountion in 35mm DIN Rail steadily

 

Technical Data

Mode Electronic / Electromagnetic
Type A / AC / B
Tripping curve B C D
Pole No. 2P / 4P
Rated voltage 230/400V~
Rated frequency 50/60Hz

 

 
Rated current 6-63A
Rated residual operating current(IΔn) 30.100.300mA
Residual operating current range 0.5 IΔn~IΔn
Rated conditional short-circuit current(lnc) 6000A / 10000A
Energy limiting class 3
Electrical and Mechanical life 20000

 

Overload Current Protection Characteristics
Test Procedure Type Test Current Initial State Tripping or Non-tripping Time Limit Expected Result Remark
A B.C.D 1.13In Cold t≤1h no tripping  
 

B

 

B.C.D

 

1.45In

 

After test A

 

t≤1h

 

tripping

The current steadily rises to the specified

value within 5s

C B.C.D 2.55In Cold 1s<t<60s tripping  
 

D

B 3In  

Cold

 

t≤0.1s

 

no tripping

Turn on the auxiliary switch to close the

current

C 5In
D 10In
 

E

B 5In  

Cold

 

t≤0.1s

 

tripping

Turn on the auxiliary switch to close the

current

C 10In
D 20In

 

 
Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N

Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N

Onccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+NOnccy RCBO Residual Current AC Breaker with Overcurrent Protection 2p 4p 3p+N
FAQ
Q: Are you trading company or manufacturer ?
A: We are manufacturer. We have 30,000 square meters of self-owned plant.

Q: Do you have any certificates?
A: Yes,we have UL, TUV, CB, SAA, CCC, CE and other certifications.

Q: How do we make a quick response to customer , 5 inquiry ?
A: Our professional team will reply you online or by email,Skype, whatsApp and so on.

Q: Do you have any exporting experience?Which countries did you export to before?
A: We have lots of exporting experience and customers in many countries,such as America, Japan,Australia,UAE,Canada,Vietnam,Turkey,Thailand,Russia,UK,etc.

Q:Can you supply samples for checking ?
A: Yes, we can supply samples, pls contact for detailed required.

Q:How long is your delivery time?
A: Generally it is within 3days for small qty. Or it is around 15-20 days to a general order.

Q: What is the standard of package of your goods?
A: Export standard package or special package according to customer requirement.

Q:How about inspection?
A: We have the whole inspection system from raw material to end products include transient test, delay test,mechanical life test and so on.Q:What is the service offered by company?

A: We have the professional engineer team which can design and develop the mould to arrive different customer requirements. We also have the professional sales team to offer good service from pre-sale to after-sale.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier