Customization: | Available |
---|---|
Type: | Low-voltage |
Structure: | Single-column Disconnector |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC Isolator switches are critical devices in electrical systems designed to isolate specific circuits for maintenance, ensuring safety by preventing current flow. These essential switches, often called isolators, come with typically one or two sets of electrical contacts aligned in series. The line side of the isolator connects efficiently to an external power supply, effectively preventing any electrical mishap.
The AC Isolator Switch is indispensable for ensuring complete de-energization of electrical circuits during routine servicing and maintenance. It acts swiftly to disconnect the circuit from the main power source, conveniently discharging any residual current, thus making the environment safe for work. In emergencies, it guarantees a rapid shutdown, ensuring no electrical currents linger when an emergency stop is needed.
Switch-disconnectors
EAS80- PM 80 R -3 RY -IM2
1 2 3 4 5 6 7
Code | Description | Code |
1 | Type of Switch disconnectors | EAS80- |
2 | Installation Form | DB:Rail mounting DC:Door interlocked PM:Panel mounting EL:Plastic enclosure box |
3 | Rated current(A) | 16:16A 20:20A 25:25A 32:32A 40:40A 63:63A 80:80A 80H:100A 100:100A 125:125A |
4 | Knob Lock | Nil:Without lock R:With lock |
5 | Poles | 2 2P 3 3P 4 4P 6 6P 8 8P (6P 8P For interlock mechanism) |
6 | Knob color | Nil:Blue knob BW:Black/white rotating handle G:Gray knob Optional with lock RY:Rotating red/yellow handle BB:Rotating black/black handle With lock without lock |
7 | Inter lock mechanism | IM2:sync IM31:normal close IM32:normal open |
Side Mount Add-on Poles
EAS80- PS R 16
1 2 3 4
No | Description | Code |
1 | Type of Switch disconnectors | EAS80- |
2 | Add on pole code | PS Sync disconnected PD Early-making PN N terminal PE Protecting earthing |
3 | Mounting type | Nil R DB/DC/EL front installation PM, reverse installation form |
4 | Rated current(A) | 16:16A 20:20A 25:25A 32:32A 40:40A 63:63A 80:80A 80H:100A 100:100A 125:125A |
Add-on auxiliary contacts
EAS80- P1 R
1 2 3
No | Description | Code |
1 | Type of Switch disconnectors | EAS80- |
2 | Auxiliary contacts Code | P1 1NO + 1NC P2 2NO |
3 | Mounting type | Nil R DB/DC/EL, front installation form PM reverse installation form |
Technical Data
Current(≤40°C) Agreed heating current | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 100A | 125A | |||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie AC-21A/B(≤690V) |
16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A | |||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie AC-22A/B |
415V | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A | ||||||||||||||||||||||||||||||||||||||||||||||||||
500V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
690V | 32A/40A | 40A/63A | 63A/80A | 63A/80A | 80A/100A | 100A/125A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie AC-23A/B |
415V | 16A/16A | 20A/20A | 25A/25A | 32A/32A | 40A/40A | 63A/63A | 80A/80A | 100A/100A | 100A/100A | 125A/125A | ||||||||||||||||||||||||||||||||||||||||||||||||||
500V | 25A/25A | 63A/63A | 80A/80A | 100A/100A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
690V | 40A/40A | 63/63A | 63A/63A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie DC-21B |
110VDC | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 100A | 125A | ||||||||||||||||||||||||||||||||||||||||||||||||||
250VDC | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 100A | 125A | |||||||||||||||||||||||||||||||||||||||||||||||||||
400VDC | 16A |
20A | 25A | 25A | 40A | 63A | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational power (3 phase) AC-23A/B |
415V | 7.5KW | 9KW | 11KW | 15KW | 18.5KW | 30KW | 37KW | 45KW | 55KW | |||||||||||||||||||||||||||||||||||||||||||||||||||
500V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
690V | 11KW | 15KW | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short circuit withstand current of fuse protection (kA rms expected value) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fuse class | 415V | 16A | 20A | 25A | 32A | 40A | 63A | 80A | 100A | 125A | |||||||||||||||||||||||||||||||||||||||||||||||||||
Rated conditional short-circuit current | 415V | 10kA | 15kA | 20kA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short circuit withstand current of circuit breaker for protection, any circuit breaker that can trip within 0.3s | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated short-time withstand current | 0.3S | 2.5kA | 3kA | 5kA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short circuit performance (unprotected) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated short-time withstand current | 1S | 1.0kA | 1.5kA | 2.5kA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated short circuit making capacity | 0.8kA | 1.4kA | 2.1kA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cable cross section | 1.5~10mm² | 2.5~35mm² | 10~70mm² | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated insulation voltage Ui | 800V | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated impulse withstand voltage Uimp | 8kV | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mechanical Endurance | 100000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ambient Temperature | Operating -25~+55°C Storage -40~+70°C |
Current(≤40°C) Agreed heating current |
63A | 80A | 100A | 63A | 80A | 100A | 63A | 80A | 100A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie AC-21A/B(≤690V) |
63A/63A | 80A/80A | 100A/100A | 63A/63A | 80A/80A | 100A/100A | 63A/63A | 80A/80A | 100A/100A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie AC-22A/B |
415V | 63A/63A | 80A/80A | 100A/100A | 63A/63A | 80A/80A | 100A/100A | 63A/63A | 80A/80A | 100A/100A | |||||||||||||||||||||||||||||||||||||||||||||||||||
500V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
690V | 40A/63A | 63A/80A | 63A/80A | 40A/63A | 63A/80A | 63A/80A | 40A/63A | 63A/80A | 63A/80A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie AC-21A/B |
415V | 63A/63A | 80A/80A | 100A/100A | 63A/63A | 80A/80A | 100A/100A | 63A/63A | 80A/80A | 100A/100A | |||||||||||||||||||||||||||||||||||||||||||||||||||
500V | 63A/63A | 63A/63A | 63A/63A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
690V | 40A/40A | 40A/40A | 40A/40A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational current Ie DC-21B | 110VDC | 63A | 80A | 100A | 63A | 80A | 100A | 63A | 80A | 100A | |||||||||||||||||||||||||||||||||||||||||||||||||||
250VDC | 63A | 80A | 100A | 63A | 80A | 100A | 63A | 80A | 100A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
400VDC | 40A | 40A | 40A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IEC rated operational power (3 phase) AC-23A/B | 415V | 30KW | 37KW | 45KW | 30KW | 37KW | 45KW | 30KW | 37KW | 45KW | |||||||||||||||||||||||||||||||||||||||||||||||||||
500V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
690V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short circuit withstand current of fuse protection (kA rms expected value) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fuse class | 415V | 63A | 80A | 100A | 63A | 80A | 100A | 63A | 80A | 100A | |||||||||||||||||||||||||||||||||||||||||||||||||||
Rated conditional short-circuit current | 415V | 15kA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short circuit withstand current of circuit breaker for protection, any circuit breaker that can trip within 0.3s | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated short-time withstand current | 0.3S | 3kA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short circuit performance (unprotected) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated short-time withstand current | 1S | 1.5kA | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated short circuit making capacity | 1.4kA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cable cross section | 2.5~35mm² | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated insulation voltage Ui | 800V | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rated impulse withstand voltage Uimp | 8kV | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mechanical Endurance | 100000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ambient Temperature | Operating -25~+55°C Storage -40~+70°C |
EXPERIENCED PV PROTECTIVE PRODUCT AND EV CHARGING STATION MANUFACTURER
Q: Are you trading company or manufacturer ?
A: We are manufacturer. We have 30,000 square meters of self-owned plant.