AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System

Product Details
Customization: Available
Type: Signal Type Arrester
Structure: Protective Gap
Still deciding? Get samples of US$ 18.6/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
17000000 RMB
Plant Area
101~500 square meters
  • AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
  • AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
  • AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
  • AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
  • AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
  • AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Installation
DIN Rail
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
Ceramic
Certification
ROHS, CE, TUV
Brand
Onccy
Nominal Discharge Current
20ka
Lmax
40ka
Pole
2p/3p
I Ec/En/UL Category
Type2
Degree of Protection
IP20
Transport Package
by Sea/Air
Specification
Export Cartons
Trademark
Onccy
Origin
China
HS Code
8536490090
Production Capacity
1000000PC/Year

Packaging & Delivery

Package Size
25.00cm * 25.00cm * 25.00cm
Package Gross Weight
1.200kg

Product Description

Product Description

AC Surge Protective Device SPD T2 385V Imax40KA 1+NPE

Product Benefits

  • 1+NPE Pole
  • AC Surge Protective Device T2
  • Discharge currents Imax 40A
  • Features (plug-in, remote signaling, compact, narrow design for little space)
  • Remote signal with RC to choose
  • Maximum Continuous Operating Voltage 385V

AC Surge Protective Device SPD T2 420V Imax40KA 3+NPE

Product Benefits

  • 3+NPE Pole
  • AC Surge Protective Device T2
  • Discharge currents Imax 40A
  • Features (plug-in, remote signaling, compact, narrow design for little space)
  • Remote signal with RC to choose
  • Maximum Continuous Operating Voltage 420V
EAP Series Surge Protection Device was designed and manufactured, complying standard GB/T18802.1 IEC/EN 61643-11 , Rated voltage 275V~,320V~,385V~,440V~,Maximum discharge current 100kA,High Energy Varistor, high effective for lightning protection.
 

Product Benefits

  • Prewired Modular Complete Unit, Consisting of A Base Part and Plug-in Protection Modules.
  • Plug-in Protection Module, Easily Installation and Maintainance.
  • High Energy Varistor, Response Time Less Than 25 Nanosecond.
  • Optional Remote Signalling Contact(FM) for Monitoring Device (Floating Changeover Contact).

Technical Data

IEC Electrical  
Nominal AC Voltage (50/60Hz) Uo /Un 230V                  230V                  230V                   400V
Maximum Continuous Operating Voltage (AC) Uc 275V                  320V                  385V                   440V
Nominal Discharge Current (8/20 μs) In 20kA                   20kA                   20kA                   20kA
Maximum Discharge Current (8/20 μs) Imax 50kA                   50kA                   50kA                   50kA
Impulse Discharge Current (10/350 μs) I Imp 12.5kA                12.5kA                10kA                   10kA
Specific Energy W/R 39kJ/Ω       39kJ/Ω       25kJ/Ω       25kJ/Ω
Charge Q 6.25As                6.25As                5As                     5As
Voltage Protection Level Up 1500V                1500V                 1800V                 2000V
Response Time tA <25ns
Back-Up Fuse (max) 160A gL
Short-Circuit Current Rating (AC) I SCCR 25kA / 50kA
TOV Withstand 5s UT 335V                  335V                  335V                  580V
  UT 440V                   440V                  440V                  765V
TOV 120min Mode Safe Fail              Safe Fail              Safe Fail              Safe Fail
Number of Ports 1
UL Electrical
Maximum Continuous Operating Voltage (AC) MCOV 275V                  320V                  385V                   440V
Voltage Protection Rating VPR 900V                  1200V                 1350V                1500V
Nominal Discharge Current (8/20 μs) In 20kA                   20kA                   20kA                   20kA
Short-Circuit Current Rating (AC) SCCR 150kA                 150kA                 150kA                 200kA
Mechanical & Environmental
Operating Temperature Range Ta -40oF to +158oF [-40oC to +70oC]
Permissible Operating Humidity RH 5%…95%
Atmospheric pressure and altitude 80k Pa … 106k Pa / -500m … 2000m
Terminal Screw Torque Mmax 39.9 Ibf·in [2.0~2.5 N.m]
Conductor Cross Section (max) 2 AWG (Solid, Stranded) / 4 AWG (Flexible)
  35mm2 (Solid, Stranded) / 25mm2 (Flexible)
Mounting 35mm DIN Rail, EN 60715
Degree of Protection IP20(built-in)
Housing Material Thermoplastic: Extinguishing Degree UL 94 V-0
Thermal Protection Yes
Operating State / Fault Indication Green: ok / Red: defect
Remote Contacts (RC) Optional
RC Switching Capacity AC:250V / 0.5A; DC:250V / 0.1A; 125V / 0.2A; 75V / 0.5A
RC Conductor Cross Section (max) 16AWG (Solid) / 1.5mm2 (Solid)
AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System

 

AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar SystemAC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
AC T2 Type Surge Protector Electrical Power System Lightning Arrester for Solar System
FAQ
Q: Are you trading company or manufacturer ?
A: We are manufacturer. We have 30,000 square meters of self-owned plant.

Q: Do you have any certificates?
A: Yes,we have UL, TUV, CB, SAA, CCC, CE and other certifications.

Q: How do we make a quick response to customer , 5 inquiry ?
A: Our professional team will reply you online or by email,Skype, whatsApp and so on.

Q: Do you have any exporting experience?Which countries did you export to before?
A: We have lots of exporting experience and customers in many countries,such as America, Japan,Australia,UAE,Canada,Vietnam,Turkey,Thailand,Russia,UK,etc.

Q:Can you supply samples for checking ?
A: Yes, we can supply samples, pls contact for detailed required.

Q:How long is your delivery time?
A: Generally it is within 3days for small qty. Or it is around 15-20 days to a general order.

Q: What is the standard of package of your goods?
A: Export standard package or special package according to customer requirement.

Q:How about inspection?
A: We have the whole inspection system from raw material to end products include transient test, delay test,mechanical life test and so on.Q:What is the service offered by company?

A: We have the professional engineer team which can design and develop the mould to arrive different customer requirements. We also have the professional sales team to offer good service from pre-sale to after-sale.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier