100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V

Product Details
Customization: Available
Type: High-voltage
Structure: Single-column Disconnector
Still deciding? Get samples of US$ 80/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
17000000 RMB
Plant Area
101~500 square meters
  • 100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
  • 100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
  • 100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
  • 100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
  • 100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
  • 100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
DC Load Disconnector
Installation
Indoor High-voltage
Operation
Electric
Grounding Mode
Not Grounding
Movement Mode
Horizontal Rotary Type
Number of Poles
2p, 3p, 4p
Grounding
Un Grounded
Series
Single-Stage
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Common Model
DIN Rail
Structure of Operating
Electric
Certification
CE, SAA
Brand
Onccy
Current
315A
Voltage Ui
1000V/1500V
Applicable Scene
Solar System/Battery Protection/DC System
Polarity
No Polarity
Impulse Withstand Voltage Uimp
12kv
Short-Time Withstand Current Lcw,1s
15ka
Transport Package
by Sea/Air
Specification
box
Trademark
Onccy
Origin
China
HS Code
8536490090
Production Capacity
1000000PC/Year

Packaging & Delivery

Package Size
25.00cm * 25.00cm * 25.00cm
Package Gross Weight
1.200kg

Product Description

Product Description

 

The difference between load break switch and circuit breakers?

 

A Load break switch is similar in structure to a disconnector (both have visible disconnection points in the disconnection state), but it can be used to open and close circuits, which in turn resembles a circuit breaker.

However, a circuit breaker can control any circuit, while aLoad break switch can only switch on or off load current, or switch off over load current, so it is only used to switch off and on circuits under normal conditions, not short circuit fault current. However, it is required that its structure can pass the fault current of short circuit time without damage.

Because the arc extinguishing device and contact of the Load break switch are designed to cut off and connect the load current, the Load break switch should be used with the fuse in most cases, and the latter is responsible for cutting off the short-circuit fault current.

The opening and closing frequency and operating life of load disconnecting switches are usually higher than those of circuit breakers.
 

EHDT Load Break Switch 1500V 400A,630A,800A 2P 3P 4P

Product Benefits

  • Easy to install
  • Added security
  • Enhanced safety
  • Flexible installation options (multiple configurations)

Features and Benefits

Easy to install

  • Wiring: Switch is non-polarized,all types of wiring and connections are possible
  • Easy access without tools,and auxiliary contacts can be integrated without tools.
  • The operating mechanism can be centered to meet the installation requirements

Safe reliable operation

  • Reliable position indicator through visible contacts.
  • The opening and closing of the switch is fully independent from the
  • speed of operation, ensuring safe operation under all conditions.
  • High temperature withstand: no derating up to 70°C

Designed for harsh environments

  • Vibration testing (from 13.2 to 100Hz at 0. 7g)
  • Shock testing (15 g during three cycles).
  • Humid temperature testing (2 cycles, 55°C/131F with 95% humidity level)
 
Detailed Photos

100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V

100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V

100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V100 AMP 3 Phase Load Break Isolator Switches Disconnector DC 150A 3p 4 Pole Main Switch 500V
FAQ
Q: Are you trading company or manufacturer ?
A: We are manufacturer. We have 30,000 square meters of self-owned plant.

Q: Do you have any certificates?
A: Yes,we have UL, TUV, CB, SAA, CCC, CE and other certifications.

Q: How do we make a quick response to customer , 5 inquiry ?
A: Our professional team will reply you online or by email,Skype, whatsApp and so on.

Q: Do you have any exporting experience?Which countries did you export to before?
A: We have lots of exporting experience and customers in many countries,such as America, Japan,Australia,UAE,Canada,Vietnam,Turkey,Thailand,Russia,UK,etc.

Q:Can you supply samples for checking ?
A: Yes, we can supply samples, pls contact for detailed required.

Q:How long is your delivery time?
A: Generally it is within 3days for small qty. Or it is around 15-20 days to a general order.

Q: What is the standard of package of your goods?
A: Export standard package or special package according to customer requirement.

Q:How about inspection?
A: We have the whole inspection system from raw material to end products include transient test, delay test,mechanical life test and so on.Q:What is the service offered by company?

A: We have the professional engineer team which can design and develop the mould to arrive different customer requirements. We also have the professional sales team to offer good service from pre-sale to after-sale.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier