Customization: | Available |
---|---|
Type: | Signal Type Arrester |
Structure: | Protective Gap |
Still deciding? Get samples of US$ 15/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
An AC Surge Protection Device (SPD) is a vital component used in electrical systems to safeguard sensitive equipment and appliances from voltage surges, also known as transient overvoltages. Voltage surges are sudden increases in voltage that can occur due to various reasons, such as lightning strikes, switching of large electrical loads, or power grid disturbances. These surges can damage or degrade electronic devices, causing malfunctions, reduced lifespan, or complete failure.
The main features of an AC Surge Protection Device are:
Product Benefits
Technical Data
IEC Electrical | ||
Nominal AC Voltage (50/60Hz) | Uo /Un | 230V 230V 230V 400V |
Maximum Continuous Operating Voltage (AC) | Uc | 275V 320V 385V 440V |
Nominal Discharge Current (8/20 μs) | In | 20kA 20kA 20kA 20kA |
Maximum Discharge Current (8/20 μs) | Imax | 50kA 50kA 50kA 50kA |
Impulse Discharge Current (10/350 μs) | I Imp | 12.5kA 12.5kA 10kA 10kA |
Specific Energy | W/R | 39kJ/Ω 39kJ/Ω 25kJ/Ω 25kJ/Ω |
Charge | Q | 6.25As 6.25As 5As 5As |
Voltage Protection Level | Up | 1500V 1500V 1800V 2000V |
Response Time | tA | <25ns |
Back-Up Fuse (max) | 160A gL | |
Short-Circuit Current Rating (AC) | I SCCR | 25kA / 50kA |
TOV Withstand 5s | UT | 335V 335V 335V 580V |
UT | 440V 440V 440V 765V | |
TOV 120min | Mode | Safe Fail Safe Fail Safe Fail Safe Fail |
Number of Ports | 1 | |
UL Electrical | ||
Maximum Continuous Operating Voltage (AC) | MCOV | 275V 320V 385V 440V |
Voltage Protection Rating | VPR | 900V 1200V 1350V 1500V |
Nominal Discharge Current (8/20 μs) | In | 20kA 20kA 20kA 20kA |
Short-Circuit Current Rating (AC) | SCCR | 150kA 150kA 150kA 200kA |
Mechanical & Environmental | ||
Operating Temperature Range | Ta | -40oF to +158oF [-40oC to +70oC] |
Permissible Operating Humidity | RH | 5%…95% |
Atmospheric pressure and altitude | 80k Pa … 106k Pa / -500m … 2000m | |
Terminal Screw Torque | Mmax | 39.9 Ibf·in [2.0~2.5 N.m] |
Conductor Cross Section (max) | 2 AWG (Solid, Stranded) / 4 AWG (Flexible) | |
35mm2 (Solid, Stranded) / 25mm2 (Flexible) | ||
Mounting | 35mm DIN Rail, EN 60715 | |
Degree of Protection | IP20(built-in) | |
Housing Material | Thermoplastic: Extinguishing Degree UL 94 V-0 | |
Thermal Protection | Yes | |
Operating State / Fault Indication | Green: ok / Red: defect | |
Remote Contacts (RC) | Optional | |
RC Switching Capacity | AC:250V / 0.5A; DC:250V / 0.1A; 125V / 0.2A; 75V / 0.5A | |
RC Conductor Cross Section (max) | 16AWG (Solid) / 1.5mm2 (Solid) |