• Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
  • Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
  • Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
  • Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
  • Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
  • Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out

Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out

Type: High-voltage
Structure: Single-column Disconnector
Installation: Indoor High-voltage
Operation: Electric
Grounding Mode: Not Grounding
Movement Mode: Horizontal Rotary Type
Samples:
US$ 60/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
EHA
Number of Poles
2p, 3p, 4p
Grounding
Un Grounded
Series
Single-Stage
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Common Model
DIN Rail
Structure of Operating
Electric
Certification
CE, SAA
Brand
Onccy
Current
315A
Voltage Ui
1000V/1500V
Applicable Scene
Solar System/Battery Protection/DC System
Polarity
No Polarity
Impulse Withstand Voltage Uimp
12kv
Short-Time Withstand Current Lcw,1s
15ka
Transport Package
by Sea/Air
Specification
box
Trademark
Onccy
Origin
China
HS Code
8536490090
Production Capacity
1000000PC/Year

Product Description

AC Load Break Disconnector Manufacturer

 

AC Load Break Disconnector switch is a type of equipment that isolates the power failure part from the live part and creates a clear break point to isolate the faulty equipment or carry out the maintenance.

A Load break switch is similar in structure to a disconnector (both have visible disconnection points in the disconnection state), but it can be used to open and close circuits, which in turn resembles a circuit breaker.

However, a circuit breaker can control any circuit, while aLoad break switch can only switch on or off load current, or switch off over load current, so it is only used to switch off and on circuits under normal conditions, not short circuit fault current. However, it is required that its structure can pass the fault current of short circuit time without damage.

The opening and closing frequency and operating life of load disconnecting switches are usually higher than those of circuit breakers.

 

EHA Load Break Disconnect Switch 400A,630A,800A 1000V 3P 4P

Product Benefits

  • Quick and perfect installation every time
  • Base, door or DIN rail mounted
  • Installation in any direction: horizontal, vertical or even at the ceiling
  • A wide variety of accessories to customize the installation,such as handles shafts, auxiliary contacts, cabling accessories and additional power poles.
  • Flexibility to plan your installation
  • Snap-on accessories available.
  • Easy to install
  • High performance

Load break switches are devices used to open an electrical circuit by isolating the source from the consumer. Whether they are manual, motorised or with a trip function, these devices ensure the on-load making, breaking and safety disconnection of low-voltage electrical circuits. Easy to assemble and easy to use, they are suitable for structures evolving in the industrial sector, public distribution, as well as emergency switching, distribution panels and motor feeders.

Modular device

  • EHD DC load break switches  are devices which are DIN rail or backplate mountable and can be integrated into a modular panel with a 45 mm front cut-out.
  • Patented switching technology
  • EHD DC load break switches with benefit from proven breaking technology based on a system of double break contacts with arc extinguishing chambers.

Product Benefits

  • Reliable position indicator through visible windows.
  • The opening and closing of the switch is fully independent from the speed of operation, ensuring safe operation under all conditions.
  • High temperature withstand: no derating up to 70°C.
  • Ambient Temperature: -40°C to +70°C.
Technical Data
Rated current le 160A 250A 315A 400A 630A 800A
Frame size EHA-315 EHA-600
Thermal current (lth) 160 250 315 400 630 800
Rated insulation voltage (Ui) 1000 1000 1000 1000 1000 1000
Rated impulse withstand voltage Uimp (KV) 12 12 12 12 12 12
Code Number of poles Rated voltage Utilisation category le(A) le(A) le(A) le(A) le(A) le(A)
EHA 3P 4P 500VAC AC -20A/AC -20B 160 250 315 400 630 800
EHA 3P 4P 500VAC AC -21A/AC -21B 160 250 315 400 630 800
EHA 3P 4P 500VAC AC -22A/AC -22B 160 250 315 400 630 800
EHA 3P 4P 500VAC AC -23A/AC -23B 160 250 315 400 630 800
EHA 3P 4P 690VAC AC -20A/AC -20B 160 250 315 400 630 800
EHA 3P 4P 690VAC AC-21A/AC -21B 160 250 315 400 630 800
EHA 3P 4P 690VAC AC -22A/AC -22B 160 250 315 400 630 800
EHA 3P 4P 690VAC AC -23A/AC -23B 160 250 315 400 630 800
EHA 3P 4P 1000VAC AC -20A/AC -20B 160 250 315 400 630 800
EHA 3P 4P 1000VAC AC -21A/AC -21B 160 250 315 400 630 800
EHA 3P 4P 1000VAC AC -22A/AC -22B 160 250 315 400 630 800
EHA 3P 4P 1000VAC AC -23A/AC -23B 160 250 315 400 630 800
Short-circuit capacity (1000VAC no protection)
 Rated short time withstand current lcw 1s (kAeff)                          kw 8 8 8 11 11 11
Rated short-circuit making capacity lcm(kA peak)- 60 ms              km 22 22 22 22 22 22
Cable 
Recommended Cu rigid cable cross section(mm) 70 120 185 240 2x185 2x240
Recommended Cu busbar width(mm) 20 20 20 25 25 25
Mechanical characteristics 
Durability (number of operating cycles) 8000 8000 8000 8000 8000 8000

Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out

Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-outLoad Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-outLoad Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-outLoad Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
Load Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-outLoad Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-outLoad Break Disconnect Switch 400A, 630A, 800A 1000V 3p 4p with a 45 mm Front Cut-out
FAQ
Q: Are you trading company or manufacturer ?
A: We are manufacturer. We have 30,000 square meters of self-owned plant.

Q: Do you have any certificates?
A: Yes,we have UL, TUV, CB, SAA, CCC, CE and other certifications.

Q: How do we make a quick response to customer , 5 inquiry ?
A: Our professional team will reply you online or by email,Skype, whatsApp and so on.

Q: Do you have any exporting experience?Which countries did you export to before?
A: We have lots of exporting experience and customers in many countries,such as America, Japan,Australia,UAE,Canada,Vietnam,Turkey,Thailand,Russia,UK,etc.

Q:Can you supply samples for checking ?
A: Yes, we can supply samples, pls contact for detailed required.

Q:How long is your delivery time?
A: Generally it is within 3days for small qty. Or it is around 15-20 days to a general order.

Q: What is the standard of package of your goods?
A: Export standard package or special package according to customer requirement.

Q:How about inspection?
A: We have the whole inspection system from raw material to end products include transient test, delay test,mechanical life test and so on.Q:What is the service offered by company?

A: We have the professional engineer team which can design and develop the mould to arrive different customer requirements. We also have the professional sales team to offer good service from pre-sale to after-sale.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now